IT  EN

Contatti

 
ACF s.r.l.
Via del Lavoro, 1/B - 2/A - 2/B

40015 Galliera Bologna
ITALY
Telefono +39 051 814190
Telefax +39 051 814358
e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
ISOTHERMAL STRUCTURE         
 
 St: Standard   O: Optional   - : Not available   FCC   FCC   FC   FA   FT

  Monocoque   -   -   -   St   St
  Modular   St   St   St   -   -
  Reinforced flooring         
  Carriages can be used   St   St   St   -   -
  Floor can be walked on           -   St   -
  Stainless steel walk-on floor   St   St   St   St   St
  Doors         
  Revolving    St   St   St    St   St
  Sliding   -   -   O   -   -
  Version with view-port   O   O   O   O   -
  Internal set-up         
  For carriage insertion   St   St   St   -   -
  For baking tin/shelf insertion   O   O   O   St   St
  For table insertion   O   O   O   -   -
  For baking cage insertion   O   O   O   -   -
  Footboard   St   St   St   -   -
  Guide-carrying racks   O   O   O   St   St
  Slide guides   O   O   O   St   St
  Finishing         
  Stainless steel interior   O   St   St   St   St
  Lamplast interior   St   O   O   -   -
  Stainless steel exterior   O   O   O   St   St
  Lamplast exterior   St   St   St   -   -
  Bumpers         
  External side door   St   St   St   O   O
  Internal side door   O   O   O   O   O
  Internal part left wall   St   St   St   O   O
  Internal part right wall   St   St   St   O   O
  Internal part bottom wall   St   St   St   O   O
  External part left wall   O   O   O   O   O
  External part right wall   O   O   O   O   O
  External part bottom wall   O   O   O   O   O
  Air feed systems         
  Horizontal upper wall   St   St   St   St   St
  Vertical wall   St   St   St   St   St

 

ELECTRICAL SYSTEM
 
St: Standard    O: Optional    - : Not available   FCC   FCC   FC   FA   FT

  Power supply    
  230V-50Hz 1F+N+T   St/O   St/O   O   St   St
  400V-50Hz 3F+N+T    O/St   O/St   St   -   -
  Other power sources   O   O   O   O   O
  Main switch   St   St   St   -   -
  Plug switch   -   -   -   St   St
  Control electronics
  Membrane keyboard   St   St   St   St   St
  Microprocessor CPU   St   St   St   St   St
  Relay driver base   St   St   St   St   St
  Display and LEDs   St   St   St   St   St
  Automatic mode control   St   St   St   St   St
  Manual mode control   St   St   St   St   St
  Defrost mode control   St   St   St   St   St
  Internal temperature control   St   St   St   St   St
  Evaporator temperature control   St   St   St   St   St
  Internal humidity control   St   St   St   St   St
  Door open signal   St   St   St   St   -
  Data buffering even in the event of a power cut   St   St   St   St   St
  Recipe saving   St   St   St   St   St
  Self-diagnosis   St   St   St   St   St
  Alarms/warnings   St   St   St   St   St
  Internal lighting system   O/St   O/St   O/St   -   -
  Light comes on automatically   O/St   O/St   O/St   -   -

 

THERMOREGULATION SYSTEM
 
St: Standard    O: Optional    - : Not available   FCC   FCC   FC   FA   FT

  Evaporator unit
  Thermostatic lamination system   St   St   St   St   St
  Automatic defrosting   St   St   St   St   St
  Defrosting over sensor   St   St   St   St   St
  High temperature safety sensor   St   St   St   St   St
  Humidity sensor   St   St   St   St   St
  Immersion-type elements   St   St   St   St   St
  Condenser units
  Open, fitted on board system   St   St   St   St   St
  Single-stage alternating compressor   St   St   St   St   St
  Air condensation   St   St   St   St   St
  Water condensation   O   O   O   O   O
  Mixed condensation   O   O   O   O   O
  Tropical working temperature   St   St   St   St   St
  Remote installation kit   O   O   O   O   O
  Anti-rain kit   O   O   O   O   O
  Soundproofing kit   O   O   O   O   O
  Wall attachment brackets   O   O   O   O   O
  First freon load   St   St   St   St   St
  First oil load   St   St   St   St   St
  Steam generator
  Version suitable for any concentration of limescale   St   St   St   St   St
  Pressure compensation system
  Equalisation valve   St   St   St   St   O
  Condensation discharge
  Automatic gravity-assisted with Firenze siphon   St   St   St   St   O
  Automatic, by evaporation               -   St
  With collection container               O   O